Sign In | Join Free | My himfr.com
Home > Electromagnetic Water Flow Meter >

High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard

    Buy cheap High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard from wholesalers
     
    Buy cheap High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard from wholesalers
    • Buy cheap High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard from wholesalers
    • Buy cheap High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard from wholesalers

    High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard

    Ask Lasest Price
    Brand Name : Runpaq
    Model Number : YR-E80
    Certification : CE, EXD
    Price : USD280 (1-5 sets) / USD240 (>5 sets)
    Payment Terms : T/T, L/C, D/A, D/P, Western Union
    Supply Ability : 2000 sets per month
    Delivery Time : 10-15 days
    • Product Details
    • Company Profile

    High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard

    magnetic heat counter, electromagnetic water flow meter Temperature: 95 °C DN80

    Description

    The magnetic flow meter does not obstruct flow, so it can be applied to clean, sanitary, dirty, corrosive and abrasive liquids. Magnetic flowmeters can be applied to the flow of liquids that are conductive, so hydrocarbons and gases cannot be measured with this technology due to their non-conductive nature and gaseous state, respectively.

    Electromagnetic flowmeters do not require much upstream and downstream straight run so they can be installed in relatively short meter runs. Magnetic flowmeters typically require 3-5 diameters of upstream straight run and 0-3 diameters of downstream straight run measured from the plane of the magnetic flowmeter electrodes.

    Features

    • Virtually no pressure loss
    • Suitable to meter for wide range of conductive liquid media
    • No Moving Parts
    • Flanges port connection
    • RS485 Standard
    • Suitable for Pipes diameter p to 2000 mm
    • Large meter ratio
    • High Accuracy
    • 4 to 20 mA / Frequency / Pulse output

    High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard

    Technical data

    Product name Electromagnetic flowmeter
    Product type Local|compact display Remote display Signal converter
    Model IYF-E IYF-F IRT
    Pipe Diameter (mm) DN10-DN2000
    Power supply 100-240 VAC / 18-36 VDC
    Accuracy + 0.5% + 0.5% + 0.5%
    Power consumption <6w <6w <6w
    Enclosure rating IP65 IP68 IP65
    Liquid temperature -25-120℃ -25-120℃ -25-120℃
    Ambient temperature -25-50℃ -25-50℃ -25-50℃
    Relative humidity 10-90% 10-90% 10-90%
    Meter ratio 1:100 1:100 1:100
    Flow direction Bi-direction flow Bi-direction flow Bi-direction flow
    Communication RS485 / Bacnet RS485 / Bacnet RS485 / Bacnet
    Signal Output 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency

    Accuracy

    Pipe Dia (mm) Velocity (m/s) Accuracy
    3-20 <0.3 + 0.25% FS
    0.3-1 + 1.0% Readout
    1-15 + 0.25% Readout
    25-600 0.1-0.3 + 0.25% FS
    0.3-1 + 0.5% Readout
    1-15 + 0.3% Readout
    700-3000 <0.3 + 0.25% FS
    0.3-1 + 1.0% Readout
    1-15 + 0.25% Readout

    Model selection

    Notice on the selection of local type and remote type:

    Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
    remote type in the following conditions:

    • Ambient temperature or converter display sunshine temperature is over 60 ℃
    • High humidity or corrosive air existed
    • Serious pipe vibration
    • Magnetic meter need be suspended or submersible, uneasily read out
    • Other abrasive condition
    No Model
    YF Electromagnetic flowmeter
    TF Turbine
    VF Votex
    LX Vane wheel
    T Ultrasonic
    E/F display mode E: compact/local display, F: remote display
    Pipe Dia Type (mm)
    xxxx

    15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400,

    500, 600, 800, 1000

    Code Accuracy
    1 + 0.5% FS
    2 + 1.0% FS
    3 + 0.2% FS
    Code Type
    N Converter: 12 / 24 VDC, pulse output
    A Transmitter: 24VDC, 4-20mA outpt
    B Intelligent, Lion battery, no local display
    G Smart, local display, 4-20mA output
    C1 Smart, local display, RS485
    C2 Smart, local display, HART
    Code Type
    S Carbon steel housing
    L Stainless steel housing
    G High pressure housing
    HL 316L electrode
    HTi Titanium electrode
    HTa Tantlum electrode
    HC Hastelloy-C electrode
    L1 Liquid media
    L2 Gas media
    P Pressure compensation
    T Temperature compensation
    PT Pressure&Temp. Compensation
    F PTFE liner
    X Rubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing,

    smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner

    Applicable metering liquid:

    • Conductive liquid media, conductivity > 5 µS/ cm
    • Various Conductive aqueous solutions, water solutions, acid & caustics
    • Abrasive slurries, sludges and grease bearing liquids, corrosive liquid, municipal tap water, waste water,dirty
      water, effluent, fibrous, viscous, paper mill, food & beverage

    Non-applicable metering medial

    • Industrial gas, compressed air, steam, or liquid with large content of gas
    • Liquid is non-conductive or low conductive, like lubricating oil, clean oil, cryogenic, cooling water, pure
      water, clean gas, etc.

    Pipe Diameter, flow volume and product dimension

    Dia Flow volume (m3/h) Product dimension (mm)
    (mm) Normal Min Max L D H H1
    15 1.5 0.06 9.5 150 95 272 254
    20 2.5 0.11 16.9 105 277 254
    25 3.5 0.18 26.5 115 283 254
    32 6 0.29 43.6 140 297 270
    40 10 0.45 67.8 150 307 280
    50 15 0.71 106.0 200 165 318 294
    65 25 1.19 179.1 185 337 313
    80 40 1.81 271.4 200 352 326
    100 60 2.83 424.1 250 220 371 344
    125 100 4.42 665 250 401 372
    150 135 6.36 954 300 285 431 403
    200 250 11.3 1696 350 340 486 460
    250 375 17.66 2650 400 395 547 511
    300 540 25.43 3817 450 445 597 565
    350 735 34.62 5195 505 657 620
    400 960 45.22 6785 500 565 717 675
    450 1200 57.23 8588 550 615 757 727
    500 1500 70 10602 600 670 817 782
    600 2160 100 15268 780 917 782
    700 2950 138 20781 700 895 1027 1068
    800 3850 180 27100 800 1015 1137 1157

    Industrial applications

    Chemical Food & beverage Paper mill
    Metallurgy Environment protection Hydraulic
    Mining Stainless Petroleum
    Pharmacy Air conditioner Effluent treatment plant
    Seawater desalination Pharmacy Water treatment

    Competitive advantage

    • Compliance to international standards: ISO14001, GB/T28001, ISO9001-2008 / GB/T50430
    • Strict process control
    • Advanced calibration equipment
    • Engineer team

    Details demonstration

    Inhouse PCB production Silicon steel transformer Calibration line

    High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard

    How to use the magnetic flow meter

    The ElectroMagnetic flowmeters measure the velocity of conductive liquids in pipes, such as water, acids, caustic, and slurries. Magnetic flowmeters can measure properly when the electrical conductivity of the liquid is greater than approximately 5μS/cm. Be careful because using magnetic flowmeters on fluids with low conductivity, such as deionized water, boiler feed water, or hydrocarbons, can cause the flowmeter to turn off and measure zero flow.

    Quality High Accuracy DN80 Electromagnetic Water Flow Meter 36VDC RS485 Standard for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shanghai Runpaiq Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)